<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-20 08-09-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 33 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
8 kHz 10 kHz 12608 0,0079
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,8 dBr -0,91 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 8:09, 20.04.2024
RT
"Ranni Plus - Politika, spolecnost, byznys, veda "
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 10 kHz MIN: 8 kHz % above 77 kHz: 0,0079 Acquired: 2024/04/20 8:09:17 Total samples: 12608 Equivalent time: 0:10:30 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,0 dBr MIN: -1,8 dBr AVE: -0,91 dBr % above 0,2 dBr: 0,0 Last value: -1,0 dBr (2024/04/20 8:09:17) 07:56 07:58 08:00 08:02 08:04 08:06 08:08 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality